Your location:Home>>

Checkout

Drop test
Leakage test
Hydraulic test
Stack test

Test Requirements for L-ring Plastic Drum
Leakage test
Air pressure:30KPA,maintain for 10 minutes. Requirement: No leakage.
Hydraulic test
Hydraulic pressure:250kPa,maintain for 30 minutes. Requirement:
No crack, no leakage.
Stack test
Stack height :3m,stack time:28day,stack temperature:=40°C;Stack
load is based on the filling goods density (Class 1:1.2 or Class 11:1.8).
Requirement: Not obvious deformation and crack.
Drop test
Drop height:1.8m;test temperature: -18°C.Requirement: No leakage
when the internal and external pressures are balanced.